Fundamental TechnologiesVoyager LECP Pages |
From Document 618-306, Revision D - selected figures:
Figure 3.3-1. LECP EDR Tape Record (Science)
| Standard Header (60 32-bit words) |
Subheader (8 32-bit words) |
Science Data (1440 32-bit words) Far Encounter Mode (1440 32-bit words) Near Encounter Mode |
The overall length of the LECP EDR is 1508 words corresponding to 80 minor frames.
Figure 3.3-3. LECP Science Record Subheader Format
Data |
Bits |
|||
|---|---|---|---|---|
| 1 | Command Word MF 32 |
Status Word 5 MF 36 |
Status Word 6 MF 36 |
Status Word 1 MF 40 |
| 3 | Status Word 2 MF 40 |
Status Word 3 MF 40 |
Status Word 4 MF 40 |
Status Word 5 MF 76 |
| 5 | Status Word 6 MF 76 |
Status Word 1 MF 80 |
Status Word 2 MF 80 |
Status Word 3 MF 80 |
| 7 | Status Word 4 MF 80 |
Command Word MF 72 |
Spare | Spare |
Spare |
LECP Science Data Word |
||||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| EDR Data Word |
Bits 31 |
16 0 | 31 | 16 0 | 31 | 16 0 | 31 | 16 0 |
| 1 | 4 R/S G1 Data Words | 4 PHA1 Data Words | ||||||
| MF 1 | MF 1 | |||||||
| 5 | 4 R/S G2 Data Words | 4 R/S G3 Data Words | ||||||
| MF 1 | MF 1 | |||||||
| 9 | 4 PHA2 Data Words | 4 R/S G4 Data Words | ||||||
| MF 1 | MF 1 | |||||||
| 13 | 4 R/S G1 Data Words | 4 PHA3 Data Words | ||||||
| MF 1 | MF 1 | |||||||
| 17 | 4 R/S G2 Data Words | 4 R/S G7 Data Words | ||||||
| MF 1 | MF 2 | |||||||
| 21 | 4 PHA1 Data Words | 4 R/S G5 Data Words | ||||||
| MF 2 | MF 2 | |||||||
| 25 | 4 R/S G1 Data Words | 4 PHA2 Data Words | ||||||
| MF 2 | MF 2 | |||||||
| 29 | 4 R/S G2 Data Words | 4 R/S G3 Data Words | ||||||
| MF 2 | MF 2 | |||||||
| 33 | 4 PHA3 Data Words | 4 R/S G6 Data Words | ||||||
| MF 2 | MF 2 | |||||||
| 37 | 4 R/S G1 Data Words | 4 PHA1 Data Words | ||||||
| MF 3 | MF 3 | |||||||
| 41 | 4 R/S G2 Data Words | 4 R/S G9 Data Words | ||||||
| MF 3 | MF 3 | |||||||
| 45 | 4 PHA2 Data Words | 4 R/S G4 Data Words | ||||||
| MF 3 | MF 3 | |||||||
49 |
4 R/S G1 Data Words | 4 PHA3 Data Words | ||||||
| MF 3 | MF 3 | |||||||
| 53 | 4 R/S G2 Data Words | 4 R/S G3 Data Words | ||||||
| MF 3 | MF 4 | |||||||
| 57 | 4 PHA1 Data Words | 4 R/S G5 Data Words | ||||||
| MF 4 | MF 4 | |||||||
| 61 | 4 R/S G1 Data Words | 4 PHA2 Data Words | ||||||
| MF 4 | MF 4 | |||||||
| 65 | 4 R/S G2 Data Words | 4 R/S G11 Data Words | ||||||
| MF 4 | MF 4 | |||||||
| 69 | 4 PHA3 Data Words | 4 R/S G6 Data Words | ||||||
| MF 4 | MF 4 | |||||||
| 73 | 4 R/S G1 Data Words | 4 PHA1 Data Words | ||||||
| MF 5 | MF 5 | |||||||
| 77 | 4 R/S G2 Data Words | 4 R/S G3 Data Words | ||||||
| MF 5 | MF 5 | |||||||
| 81 | 4 PHA2 Data Words | 4 R/S G4 Data Words | ||||||
| MF 5 | MF 5 | |||||||
| 85 | 4 R/S G1 Data Words | 4 PHA3 Data Words | ||||||
| MF 5 | MF 5 | |||||||
| 89 | 4 R/S G2 Data Words | 4 R/S G8 Data Words | ||||||
| MF 5 | MF 6 | |||||||
| 93 | 4 PHA1 Data Words | 4 R/S G5 Data Words | ||||||
| MF 6 | MF 6 | |||||||
| 97 | 4 R/S G1 Data Words | 4 PHA2 Data Words | ||||||
| MF 6 | MF 6 | |||||||
| 101 | 4 R/S G2 Data Words | 4 R/S G3Data Words | ||||||
| MF 6 | MF 6 | |||||||
| 105 | 4 PHA3 Data Words | 4 R/S G6 Data Words | ||||||
| MF 6 | MF 6 | |||||||
| 109 | 4 R/S G1 Data Words | 4 PHA1 Data Words | ||||||
| MF 7 | MF 7 | |||||||
| 113 | 4 R/S G2 Data Words | 4 R/S G10 Data Words | ||||||
| MF 7 | MF 7 | |||||||
| 117 | 4 PHA2 Data Words | 4 R/S G4 Data Words | ||||||
| MF 7 | MF 7 | |||||||
| 121 | 4 R/S G1 Data Words | 4 PHA3 Data Words | ||||||
| MF 7 | MF 7 | |||||||
| 125 | 4 R/S G2 Data Words | 4 R/S G3 Data Words | ||||||
| MF 7 | MF 8 | |||||||
| 129 | 4 PHA1 Data Words | 4 R/S G5 Data Words | ||||||
| MF 8 | MF 8 | |||||||
| 133 | 4 R/S G1 Data Words | 4 PHA2 Data Words | ||||||
| MF 8 | MF 8 | |||||||
| 137 | 4 R/S G2 Data Words | 4 R/S G12 Data Words | ||||||
| MF 8 | MF 8 | |||||||
| 141 | 4 PHA3 Data Words | 4 R/S G6 Data Words | ||||||
| MF 8 | MF 8 | |||||||
The preceding data structure for MF 1-8 is repeated 9 more times (a total of 1440 32-bit words) with the following R/S Group exceptions:
| MF | EDR Data Words | R/S Group |
| 12; 52 | 211, 212; 931, 932 | 13 |
| 16; 56 | 283, 284; 1003, 1004 | 14 |
| 20; 60 | 355, 356; 1075, 1076 | 15 |
| 24; 64 | 427, 428; 1147, 1148 | 11 |
| 28; 68 | 499, 500; 1219, 1220 | 12 |
| 32; 72 | 571, 572; 1291, 1292 | 13 |
| 36; 76 | 643, 644 (LECP Status words 5 & 6); 1363, 1364 (Status words 5 & 6) |
16 |
| 40; 80 | 715 (Status words 1 & 2) 716 (Status words 3 & 4) 1435 (Status words 1 & 2) 1436 (Status words 3 & 4) |
17 |
| EDR Data Word |
31 | 16 0 | 31 | 16 0 | 31 | 16 0 | 31 | 16 0 |
| 1 | 4 R/S G1 Data Words - MF 1 | 4 R/S G2 Data Words - MF 1 | ||||||
| 5 | 4 R/S G3 Data Words - MF 1 | 4 R/S G4 Data Words - MF 1 | ||||||
| 9 | 4 R/S G5 Data Words - MF 1 | 4 R/S G6 Data Words - MF 1 | ||||||
| 13 | 4 R/S G1 Data Words - MF 1 | 4 R/S G2 Data Words - MF 1 | ||||||
| 17 | 4 R/S G3 Data Words - MF 1 | 4 R/S G4 Data Words - MF 2 | ||||||
| 21 | 4 R/S G7 Data Words - MF 2 | 4 R/S G9 Data Words - MF 2 | ||||||
| 25 | 4 R/S G1 Data Words - MF 2 | 4 R/S G2 Data Words - MF 2 | ||||||
| 29 | 4 R/S G3 Data Words - MF 2 | 4 R/S G4 Data Words - MF 2 | ||||||
| 33 | 4 R/S G15 Data Words - MF 2 | 4 R/S G17 Data Words - MF 2 | ||||||
| Status | Status | |||||||
The sequence above repeats 8 more times |
||||||||
| 325 | 4 R/S G18 Data Words - MF 19 | 4 R/S G18 Data Words - MF 19 | ||||||
| 329 | 4 R/S G18 Data Words - MF 19 | 4 R/S G18 Data Words - MF 19 | ||||||
| 333 | 4 R/S G18 Data Words - MF 19 | 4 R/S G18 Data Words - MF 19 | ||||||
| 337 | 4 R/S G18 Data Words - MF 19 | 4 R/S G18 Data Words - MF 19 | ||||||
| 341 | 4 R/S G18 Data Words - MF 19 | 4 R/S G18 Data Words - MF 20 | ||||||
| 345 | 4 R/S G18 Data Words - MF 20 | 4 R/S G18 Data Words - MF 20 | ||||||
| 349 | 4 R/S G18 Data Words - MF 20 | 4 R/S G18 Data Words - MF 20 | ||||||
| 353 | 4 R/S G18 Data Words - MF 20 | 4 R/S G18 Data Words - MF 20 | ||||||
| 357 | 4 R/S G18 Data Words - MF 20 | 4 R/S G18 Data Words - MF 20 | ||||||
The structure of words 1 - 360 is repeated |
||||||||
Return to Voyager LECP Data Analysis Handbook Table of
Contents.
Return to Fundamental Technologies Home Page.
Last modified 4/22/05, Tizby Hunt-Ward
tizby@ftecs.com